A Second Case Study of Field Test Results for Comparison of Roof Bolter Dry Collection System with Wet Collection System

Society for Mining, Metallurgy & Exploration
W. R. Reed S. S. Klima A. Mazzella G. Ross G. Roberts J. Deluzio
Organization:
Society for Mining, Metallurgy & Exploration
Pages:
14
File Size:
3380 KB
Publication Date:
May 11, 2022

Abstract

The abstract discusses the problem of silicosis among roof bolter operators in coal mines due to respirable quartz dust (RCS) exposure. It presents a study comparing a new wet box collection system to the traditional dry box system. The wet box system uses water to saturate collected material, reducing RCS exposure during cleaning. The study found that the wet box system significantly reduced RCS exposures and quartz content in samples compared to the dry box system.
Citation

APA: W. R. Reed S. S. Klima A. Mazzella G. Ross G. Roberts J. Deluzio  (2022)  A Second Case Study of Field Test Results for Comparison of Roof Bolter Dry Collection System with Wet Collection System

MLA: W. R. Reed S. S. Klima A. Mazzella G. Ross G. Roberts J. Deluzio A Second Case Study of Field Test Results for Comparison of Roof Bolter Dry Collection System with Wet Collection System. Society for Mining, Metallurgy & Exploration, 2022.