Application Of Pile Test Data For The Foundation Design Of Rail Viaduct At Carrum, Victoria

Deep Foundations Institute
Suthagarann Visvalingam Cillian Mc Colgan Nick M. Withers
Organization:
Deep Foundations Institute
Pages:
10
File Size:
991 KB
Publication Date:
Nov 1, 2022

Abstract

The level crossings removal project in Victoria is removing 75 level crossings across Melbourne to improve safety by separating trains from traffic, with other benefits such as reduced congestion, an upgraded road network, connected communities and support of urban regeneration. The level crossing at Station Street in Carrum forms part of the scope being delivered by the Southern Program Alliance (SPA), which is delivering level crossing removal works associated with the Frankston Train Line. At Station Street, a rail viaduct consisting of 19 spans and totalling approximately 545 m in length is under construction to remove the former level crossing. The viaduct consists of two parallel reinforced concrete Utrough girders and steel trough girders, one for each rail line. The foundations of the rail viaduct are founded on groups of Continuous Flight Auger (CFA) piles. The characterisation of geological units encountered at Carrum for the foundation design has been based on insitu testing and interpretation of test results from high strain dynamic pile testing (PDA) and Case Pile Wave Analysis Program (CAPWAP) from the Seaford Road Bridge, located approximately three kilometres South of Carrum, in similar ground conditions. By conducting pile load-deformation analyses based on pile testing significant savings were made for the client compared to the original design which was based on more traditional empirical correlations. This paper discusses the pile design methodology adopted using pile test data for this viaduct foundation. The results of this assessment are also compared to existing empirical correlations, and the limitations are discussed. The performance of the adopted pile design methodology using pile test data at Carrum rail viaduct is also discussed.
Citation

APA: Suthagarann Visvalingam Cillian Mc Colgan Nick M. Withers  (2022)  Application Of Pile Test Data For The Foundation Design Of Rail Viaduct At Carrum, Victoria

MLA: Suthagarann Visvalingam Cillian Mc Colgan Nick M. Withers Application Of Pile Test Data For The Foundation Design Of Rail Viaduct At Carrum, Victoria. Deep Foundations Institute, 2022.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account