Bubble Flow Pattern Detection in the Water Model of a Metal Treatment Unit.

- Organization:
- The Australasian Institute of Mining and Metallurgy
- Pages:
- 6
- File Size:
- 727 KB
- Publication Date:
- Jan 1, 1995
Abstract
A water/air model was developed to simulate the refining of molten aluminium by the sparging of gas through an impeller. The optimal gas dispersion depends upon selecting the correct gas rate for a given impeller rotational velocity to prevent flooding or channelling. Correlations illustrating this flooding behaviour exist for standard impellers within standard tank geometries. However the validity of these correlations has not been substantiated for gas dispersion in high temperature molten metals with non-standard tank and impeller dimensions.
Citation
APA:
(1995) Bubble Flow Pattern Detection in the Water Model of a Metal Treatment Unit.MLA: Bubble Flow Pattern Detection in the Water Model of a Metal Treatment Unit.. The Australasian Institute of Mining and Metallurgy, 1995.