Abstract
An extensive laboratory campaign was conducted to find a suitable water  soluble collector to replace diphenylguanidine (DPG) in the matte  separation process. The examination of the collectors was done by  measuring the rate of flotation and the best candidate collectors were  selected on the basis of the rate parameters. As a result of this search  mercaptobenzothiazole (MBT) was selected for a plant trial. A plant trial  of two weeks duration confirmed that MBT will produce separations at  least as good as those obtained with DPG.
Citation
APA: (1993) Choosing a Water Collector for Matte Separation