This paper extends the existing knowledge associated with the design and placement of prefabricated pastefill barricades through a consideration of asymmetric drive geometry and conditions. The load capacity of prefabricated barricades and their failure modes are considered in relation to abutment geology and barricade geometry that includes curvature and span and drive geometry that includes abutment angles, haunch angles and misalignment. Design charts are provided for typical barricade sizes to provide general guidance for design capacities and optimising location placement based on asymmetric drive geometry. A recent barricade failure is considered in relation to the drive geometry and the potential impact it had on the installed capacity.
Citation
APA: