Controlling dust exposures in longwall mining utilizing a simple barrier

The National Institute for Occupational Safety and Health (NIOSH)
Daniel D. Sweeney
Organization:
The National Institute for Occupational Safety and Health (NIOSH)
Pages:
4
File Size:
306 KB
Publication Date:
Jan 1, 2009

Abstract

The United States coal mining industry has traditionally experienced difficulty in controlling dust levels below the occupational exposure limit. While improvements in face ventilation and water spray nozzles have decreased dust exposures, approximately eight percent of experienced coal miners are still developing Coal Worker?s Pneumoconiosis. This investigation tested the feasibility of enhancing existing engineering dust controls by mounting a simple barrier on a longwall shearer that separated the operators from the cutting drums. The barrier was constructed and tested above ground at the National Institute for Occupational Safety and Health Pittsburgh Research Laboratory longwall gallery test facility. A 96-percent reduction of respirable dust occurred at the headgate sampling position when tested at 2.4 m/sec (480 ft/min). The average dust level decreased from 39 mg/m3 to 1.5 mg/m3 by utilizing the barrier.
Citation

APA: Daniel D. Sweeney  (2009)  Controlling dust exposures in longwall mining utilizing a simple barrier

MLA: Daniel D. Sweeney Controlling dust exposures in longwall mining utilizing a simple barrier. The National Institute for Occupational Safety and Health (NIOSH), 2009.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account