Abstract
High Pressure Grinding Rolls (HPGR) are mostly used prior to pelletising processes to increase
the specific surface area (SSA) of iron ore concentrate. For expressing SSA, the Blaine index is utilised
as one of the most important dimensional properties of iron ore pellet feed. ISO 21283 is a standard test
method that explains the manual of Blaine air-permeability apparatus for determination of this
parameter. In this standard, the disaggregation method is based on passing the minus of 1 mm samples
from the 0.150 mm sieve. The disaggregation process has an effective role on the results of Blaine airpermeability
test especially for regrinding HPGR products. In this research, firstly the Blaine index of
samples was measured without disaggregation. Following this, disaggregation was done by passing the
minus of 1 mm samples through three sieves with different dimensions, 0.150, 0.090 and 0.045 mm,
separately, and the Blaine index was calculated for each one. Finally, lab-mill with rubber balls, called
Jar mill, was investigated as another option. Screen analysis and image analysis with SEM were
performed to evaluate the effects of the sample's disaggregation on the size distribution and
agglomeration of samples. The results showed that the disaggregation method with sieve size 0.150 mm,
according to ISO 21283, was not applicable for HPGR products because the particles were still stuck
together. In addition, the disaggregation method with the sieve size 0.045 mm or with Jar mill offered
reasonable results.
Keywords: Disaggregation, Blaine index, specific surface area, regrinding HPGR, ISO 21283, Jar
mill
Citation
APA:
(2020) Determination of the influences of sample disaggregation methods on the Blaine index of regrinding HPGR product, N. Esmaeili, A.D. Ahmadabadi, R. Hejazi, M. Saghaeian, and V. SheikhzadehMLA: Determination of the influences of sample disaggregation methods on the Blaine index of regrinding HPGR product, N. Esmaeili, A.D. Ahmadabadi, R. Hejazi, M. Saghaeian, and V. Sheikhzadeh. The Southern African Institute of Mining and Metallurgy, 2020.