Example Of The Refractory Corrosion Test Work With Nickel Matte

The Minerals, Metals and Materials Society
D. Gregurek A. Ressler A. Spanring C. Pichler
Organization:
The Minerals, Metals and Materials Society
Pages:
8
File Size:
549 KB
Publication Date:
Jan 1, 2015

Abstract

In order to improve the refractory lining life at one of the RHI key customer test procedures were developed within a two years collaboration project. In the first year of cooperation detailed refractory corrosion work in the rotary kiln with Ca-ferritic slag was performed. The main results of the second year of cooperation, reported in this article, involve a detailed testing work with nickel matte and pre-selected refractory brands which was performed in TBRC. A first part of this work was a complete chemical and mineralogical characterization as well as FactSage calculations carried out on provided matte samples. According to these results testing in the TBRC was realized at different process temperatures with several magnesia-chromite bricks. Based on the mineralogical investigation a high chemothermal load caused by sulfidic matte resulted in a deep reaching infiltration of the brick microstructure and partly corrosion of main brick components.
Citation

APA: D. Gregurek A. Ressler A. Spanring C. Pichler  (2015)  Example Of The Refractory Corrosion Test Work With Nickel Matte

MLA: D. Gregurek A. Ressler A. Spanring C. Pichler Example Of The Refractory Corrosion Test Work With Nickel Matte. The Minerals, Metals and Materials Society, 2015.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account