Graphical Representation Of The Operating Points For Two-Fan Ventilation Systems (ceafb6fb-81cc-4186-a358-a8cdd7507260)

- Organization:
- The American Institute of Mining, Metallurgical, and Petroleum Engineers
- Pages:
- 5
- File Size:
- 270 KB
- Publication Date:
- Jan 1, 1986
Abstract
A graphical technique by which the operating points for a two-fan ventilation system can be represented as the intersection of the modified fan curves is described. In constructing the diagram, the air quantities associated with the fans are considered to be independent variables and used as the axes of a rectangular coordinate system. The diagram may include, in addition to the modified fan curves, contour lines for resistances, pressures, and air powers. Procedures for drawing the diagram are discussed and illustrated with an example of the ventilation system.
Citation
APA:
(1986) Graphical Representation Of The Operating Points For Two-Fan Ventilation Systems (ceafb6fb-81cc-4186-a358-a8cdd7507260)MLA: Graphical Representation Of The Operating Points For Two-Fan Ventilation Systems (ceafb6fb-81cc-4186-a358-a8cdd7507260). The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1986.