Abstract
Sanitary land filling has become one of the most widely used methods of disposing of solid refuse. A principal concern of regulatory agencies and the public itself is that landfill operations do not degrade the physical environment, including water resources, and the ground-water reservoir in particular. Knowledge of ground-water and engineering geology can guide landfill operations into suitable terranes or develop measures to compensate for natural limitations at a particular site. Experience and research in Illinois suggest four activities relating to landfill disposal that warrant attention by geologists and engineers: (1) regional delineation of favorable and unfavorable hydrogeologic conditions to facilitate planning and preliminary screening of potential landfill sites; (2) site evaluations, with considerations of geologic materials, topography, water levels, flow systems, and local occurrence and use of water resources; (3) research on aspects of the hydrogeologic environment that control effects of, or are modified by, landfills; and (4) formulation of practices in the siting, construction, and operation of landfills that prevent, mitigate, or isolate deleterious effects. The first two activities are basically in the domain of earth science, requiring the application of fundamental concepts of geology and hydrology and conventional site-exploration methods. The third activity, research, requires contributions from geology as well as other disciplines, including soil physics, sanitary engineering, and chemistry. The fourth calls for policy decisions by regulatory agencies and elected officials, using the contributions of scientists and engineers. Throughout history, man has disposed of unwanted materials by dumping. As urbanization has increased, haphazard dumping practices have given way to disposal under more controlled conditions because of increasing congestion of population and production of waste and greater concern for public health and environmental amenities. Many states and communities have already outlawed open dumping and open burning of refuse. The only practical methods of disposal of large volumes of refuse, therefore, are contained, high-temperature incineration, or burial in a sanitary landfill. In Illinois, regulation of solid waste disposal has been delegated to the Environmental Protection Agency. Each session of the legislature since 1965 has passed increasingly strict laws regulating waste diposal. As a result, the work of evaluating sanitary landfill sites has increased significantly for both the Department of Public Health, now the Environmental Protection Agency, and the Illinois State Geological Survey, which advises the Agency on matters of ground-water geology and pollution. In fact, our ground-water staff spends as much time on studies relating to waste disposal, primarily sanitary landfills, as on ground-water resource studies. Many other geological agencies are experiencing similar demands for increased assistance in solving waste-disposal problems. This paper summarizes some of the salient features of the sanitary landfill concept, describes activities of the Illinois Geological Survey in ground-water and engineering geology relating to landfills, and suggests policies that need consideration. A sanitary landfill is located and operated in such a way that vermin and pests, nuisances, and degradation of air and water are kept at acceptable levels. Some of the physical requirements of a sanitary landfill are all-weather roads for year-round access, fences to retain blowing paper, a daily cover of at least six inches of suitable earth material, and a final cover of at least 2 ft of earth material. Dumping into or adjacent to standing water generally is not allowed. Two common operating techniques are used. In the first, trenches are dug, the refuse is placed in them, and the earth removed from the trenches is used to cover the waste. In the second method, area fill, refuse is placed in low ground and covered with earth from adjacent high areas. The hydrology of the site is a prime consideration in locating sanitary landfills. Putrescible refuse, if saturated above field capacity, produces a leachate that usually has a high concentration of dissolved solids.2 As the leachate also acts as an agent for transporting bacterial pollutants, it constitutes a potential pollution hazard. To reduce the production of leachates, the topography of the landfill area should be such that surface water will not flow into or through the fill. Operations that will result in refuse disposal below or near the highest known water-table elevation may be required to take corrective or preventive measures to protect the ground water. In practice, under humid conditions such as prevail in Illinois, locations where disposal can take place above the water table are relatively few because surficial materials are commonly fine-grained, which permits slow gravity drainage and results in high degrees of saturation (100% moisture content) near the surface. At some sites, although disposal has taken place above the water table, ground-water mounds have developed, resulting in permanent saturation of the refuse. Permeability barriers usually are required to protect the ground-water reservoir from degradation by leachates. The convention in Illinois is to have a minimum of
Citation
APA:
(1972) Ground-Water and Engineering Geology in Siting of Sanitary Landfills (e3bb8b8f-b2ae-4683-b516-f1f89a0fe208)MLA: Ground-Water and Engineering Geology in Siting of Sanitary Landfills (e3bb8b8f-b2ae-4683-b516-f1f89a0fe208). The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1972.