Abstract

"1 INTRODUCTIONThe use of nondestructive testing (NDT) methods to evaluate the integrity of Augered Cast-in-Place (ACIP) and Drilled Displacement (DD) piles has been a subject of significant debate among engineers, contractors and NDT practitioners. This guideline document will illustrate the importance of reviewing all available information in conjunction with the NDT records. ACIP and DD piles have unique properties that must be considered when using a specific NDT method. Any evaluation of the integrity of an ACIP or DD pile must also include a thorough review of the detailed pile installation records and the site specific soil conditions. Long or theoretical descriptions of the methods have not been included in this publication. More detailed information about these NDT methods including their theoretical and historical backgrounds can be found in DFI’s Manual for Non Destructive Testing and Evaluation of Drilled Shafts (2004). Additional information can also be found in the more comprehensive textbook Nondestructive Testing of Deep Foundations by Hertlein and Davis (2006).1.1 PurposeThe intent of this guideline is to provide practical guidance for the proper interpretation of NDT results on ACIP and DD piles. Short descriptions of the main integrity methods available are provided along with several examples of how to use all of the information available to make sound engineering judgments about the results. This publication is a state-of-the-practice guideline to promote accurate engineering evaluations.For engineers inexperienced with NDT, these guidelines provide sufficient background information on NDT methods to help understand the limitations of the testing, assess the results presented to them, and formulate appropriate questions. This is particularly important for engineers charged with the responsibility to determine from those results what, if any, consequences there may be on the performance of the structure under construction."
Citation

APA:  (2016)  Guideline for Interpretation of Nondestructive Integrity Testing of Augered Cast-In-Place and Drilled Displacement Piles

MLA: Guideline for Interpretation of Nondestructive Integrity Testing of Augered Cast-In-Place and Drilled Displacement Piles. Deep Foundations Institute, 2016.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account