Abstract
Genstar's underground mine at Texas, MD experienced a failure of the mine roof and subsequent damage to an underground backfill caused by surface floodwaters. A hydraulic backfilling program was developed in house to stabilize temporary repairs to the mine roof, replace 2300 yards of pneumatically stowed backfill, and complete a permanent repair to the mine roof. A flowable backfill material was developed, tested, and later marketed as the result of experience gained during this project. In addition, Genstar personnel developed backfilling techniques to meet the requirements of the repairs and completed work without the additional expense of non company services or contractors.
Citation
APA: