Measurement Of The Oxygen Potential Of Non-Ferrous Slags With An Ex-Situ Electrochemical Device (e2f7d454-503b-42f7-857d-778dde49d307)

- Organization:
- The Minerals, Metals and Materials Society
- Pages:
- 7
- File Size:
- 277 KB
- Publication Date:
- Jan 1, 2003
Abstract
A method using an ex-situ electrochemical measurement device was developed to determine the oxygen potential of non-ferrous metallurgical slags. The electrochemical cell consists of the molten slag sample, an inert Ir electrode, a stabilized Zr02 solid electrolyte and a NiINiO reference electrode. Different slags from non-ferrous pyrometallurgical processes were analysed at 1100 and 1200°C and pO2 values between 10-3 and 10.12 bar were obtained. The measurements were evaluated with? thermodynamic calculations and using processing considerations. It was found that the reproducibility and stability of the measurement was significantly improved by shielding the molten slag from the atmosphere by a thin layer of carbon, especially for slags with a low oxygen potential.
Citation
APA:
(2003) Measurement Of The Oxygen Potential Of Non-Ferrous Slags With An Ex-Situ Electrochemical Device (e2f7d454-503b-42f7-857d-778dde49d307)MLA: Measurement Of The Oxygen Potential Of Non-Ferrous Slags With An Ex-Situ Electrochemical Device (e2f7d454-503b-42f7-857d-778dde49d307). The Minerals, Metals and Materials Society, 2003.