OFR-11-83 Portable Trailing Cables, Splices, And Couplers Design And Installation Considerations

- Organization:
- The National Institute for Occupational Safety and Health (NIOSH)
- Pages:
- 96
- File Size:
- 31696 KB
- Publication Date:
- Jan 1, 1982
Abstract
This report summarizes the work performed on Bureau of Mines Contract J0199106, "Portable Trailing Cables, Splices, and Couplers - Design and Installation Considerations," from May 1, 1979 until December 31, 1981. Splice installations and considerations for the possible use of conductive-rubber shielding in low-voltage trailing cables as well as coupler installations in high-voltage cables were the principal tasks. Flammability measurements on cable components and general testing facilities for mine electrical equipment were secondary tasks. Theoretical and empirical data indicate that conductive rubber with high resistivity values is an unsatisfactory shield design for current-sensing fault detection. Elimination of partial discharge in coupler installations requires meticulous care.
Citation
APA: