OFR-209-83 Reverse Performance Characteristics Of Main Mine Fans (2730c789-b762-4f09-a20d-2003448b9a66)

- Organization:
- The National Institute for Occupational Safety and Health (NIOSH)
- Pages:
- 65
- File Size:
- 16004 KB
- Publication Date:
- Jan 1, 1983
Abstract
During a mine fire or other emergency, it may be desirable to reverse the airflow in order to provide an escapeway or to isolate a fire. Also, in colder areas, the airflow may be reversed to prevent ice buildup. When reversing main mine fans, the mine operator usually does not know what operating characteristics of flow and pressure to expect. Laboratory and field tests of vane axial main mine fans in the 7- to 9-ft diameter size range were conducted to establish forward and reverse performance characteristics under controlled conditions and at typical mine installations. The data obtained suggest that reverse performance characteristics are dependent upon the blade angle and the hub to tip ratio. There is also evidence that reverse performance can be predicted for a family of blade angles and a given hub to tip ratio. Generally, quantity of air is 30 to 65% less in reverse than when operating in the normal forward mode.
Citation
APA:
(1983) OFR-209-83 Reverse Performance Characteristics Of Main Mine Fans (2730c789-b762-4f09-a20d-2003448b9a66)MLA: OFR-209-83 Reverse Performance Characteristics Of Main Mine Fans (2730c789-b762-4f09-a20d-2003448b9a66). The National Institute for Occupational Safety and Health (NIOSH), 1983.