OFR-87(2)-79 High And Medium Voltage Trailing Cable Splices And Connections - Vol. II - Trailing Cable Couplers

- Organization:
- The National Institute for Occupational Safety and Health (NIOSH)
- Pages:
- 106
- File Size:
- 27699 KB
- Publication Date:
- Jan 1, 1978
Abstract
This report describes a study of the factors which affect medium voltage (661 - 1000 volts) and high voltage (1001 - 7500 volts) trailing cable couplers for use in underground coal mines to connect trailing rabies. Improvements in quality, dependability, and safety of medium and high voltage couplers are presented in the form of requirements for couplers. The results of an investigation of high voltage trailing cable coupler design and of whether trailing cable couplers must have a metallic shell as required by CFR 30 part 75.805 are presented. Conclusions and recommended research programs are included that describe the present situation and future development approaches.
Citation
APA:
(1978) OFR-87(2)-79 High And Medium Voltage Trailing Cable Splices And Connections - Vol. II - Trailing Cable CouplersMLA: OFR-87(2)-79 High And Medium Voltage Trailing Cable Splices And Connections - Vol. II - Trailing Cable Couplers. The National Institute for Occupational Safety and Health (NIOSH), 1978.