On-Line Size Analysis in Grinding Circuit Control

The American Institute of Mining, Metallurgical, and Petroleum Engineers
Larry S. Diaz Paul M. Musgrove
Organization:
The American Institute of Mining, Metallurgical, and Petroleum Engineers
Pages:
7
File Size:
568 KB
Publication Date:
Jan 1, 1974

Abstract

Recent tests conducted at Inspiration Consolidated Copper Co. examined some aspects of the value of a continuous measurement of particle size to the operation and control of a mill grinding circuit. Inspiration's control objectives and kinds of control systems developed in recent years to attain these objectives are outlined. A description is given of the arrangement of the test circuit at Inspiration and also of the systems used to measure particle size of the cyclone overflow product in these tests. Use of on-line size measurement for the analysis and improvement of grinding circuit performance is illustrated by relating how two important relationships were detected. Finally, the performance of a particle-size-based control system is described, including preliminary conclusions as to increased productivity.
Citation

APA: Larry S. Diaz Paul M. Musgrove  (1974)  On-Line Size Analysis in Grinding Circuit Control

MLA: Larry S. Diaz Paul M. Musgrove On-Line Size Analysis in Grinding Circuit Control. The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1974.