Online SO2 Analysis Of Copper Converter Off-Gas

- Organization:
- The Minerals, Metals and Materials Society
- Pages:
- 11
- File Size:
- 295 KB
- Publication Date:
- Jan 1, 1999
Abstract
The off gas from the #5 converter at BHP Copper's San Manuel smelter was analyzed continuously over a period of several weeks using an online sulfur dioxide analyzer. These data have shown that the oxygen utilization efficiency of this copper converter was somewhat lower than anticipated, and that oxygen efficiency declines significantly during the copper blow. A sharp reduction in sulfur dioxide generation was consistently observed at the end of the copper blow, which could be used by converter operators to prevent over-blowing and minimize rolling out of stack.