Performance Characteristics for Large Sections of Welded Wire Screen With Multiple Pull Patterns

International Conference on Ground Control in Mining
Timothy J. Batchler Ted M. Klemetti Timothy J. Matthews
Organization:
International Conference on Ground Control in Mining
Pages:
6
File Size:
1578 KB
Publication Date:
Jan 1, 2018

Abstract

"From 2011–2016, there were 1,511 documented injuries, including 7 fatalities, from ground falls in underground coal mines in the United States. The majority of these ground-fall injuries were not caused by a major roof collapse, but from falls of smaller rocks from the immediate roof. Roof screen can significantly reduce the number of these injuries and has been widely used in underground coal mines for surface control. Because of the potential of reducing ground-fall injuries, the National Institute for Occupational Safety and Health (NIOSH) is further evaluating the performance characteristics of welded wire screen as used in underground coal mines by conducting a laboratory testing program using the Mine Roof Simulator (MRS) in Pittsburgh, PA.The load-displacement characteristics of an 8-ft x 12-ft panel of 8-gauge welded screen were evaluated using a newly designed, large laboratory screen test frame with multiple load pull locations. This screen was tested in a configuration that simulates current installation practices in U.S. coal mines. In this study, the effects of varying the number and position of the load pull location on the screen performance were evaluated. Ultimately, the type of information obtained in this and similar studies can be used to aid in developing wire roof screen design criteria and to assist mine operators in the selection and use of roof screen in underground mines.INTRODUCTIONThe large majority of ground-fall injuries are caused by falls of smaller rocks from the immediate roof. Various controls are currently being used in mines to control this surface rock, including the use of wire roof screen. In mines where wire roof screen has been installed, injuries from rock falls have been reduced dramatically (Robertson and Hinshaw, 2001). Roof screen has the potential to prevent hundreds of injuries caused by the fall of small rocks between permanent roof supports (Compton et al., 2007). Because of this potential for reducing ground-fall injuries, the National Institute for Occupational Safety and Health (NIOSH) is evaluating the performance characteristics of welded wire screen as used in underground coal mines by conducting a laboratory testing program in the Mine Roof Simulator (MRS) in Pittsburgh, PA."
Citation

APA: Timothy J. Batchler Ted M. Klemetti Timothy J. Matthews  (2018)  Performance Characteristics for Large Sections of Welded Wire Screen With Multiple Pull Patterns

MLA: Timothy J. Batchler Ted M. Klemetti Timothy J. Matthews Performance Characteristics for Large Sections of Welded Wire Screen With Multiple Pull Patterns. International Conference on Ground Control in Mining, 2018.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account