Portable instruments for measuring tailpipe diesel particulate in underground mines

Society for Mining, Metallurgy & Exploration
J. Noll
Organization:
Society for Mining, Metallurgy & Exploration
Pages:
8
File Size:
1644 KB
Publication Date:
Oct 1, 2013

Abstract

There is a need for direct tailpipe sampling of diesel vehicles in mines in order to determine the effects of an emissions-based maintenance program, evaluate control technologies such as diesel particulate filters and identify the worst diesel particulate matter (DPM) emitters in a fleet of vehicles. therefore, this study examined the performance of three portable instruments: a personal dust monitor (PDM) manufactured by thermo Scientific, a prototype elemental carbon monitor (Airtec) manufactured by FLIr and a prototype Ae91 instrument from Magee Scientific. These instruments were evaluated on the basis of their ability to provide direct reading tailpipe analysis for DPM. It was determined that the average bias of the tailpipe results from the PDM and the Airtec were 3±12% and 4±20%, respectively, when compared to the standard method of determining tailpipe particulate concentrations from a diluted exhaust. It was also determined that the Ae91 instrument correlated with the standard method.
Citation

APA: J. Noll  (2013)  Portable instruments for measuring tailpipe diesel particulate in underground mines

MLA: J. Noll Portable instruments for measuring tailpipe diesel particulate in underground mines. Society for Mining, Metallurgy & Exploration, 2013.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account