Rammed Aggregate Pier Load Test Results
- Organization:
- Deep Foundations Institute
- Pages:
- 6
- File Size:
- 2010 KB
- Publication Date:
- Feb 1, 2024
Abstract
The Middle East consists of vast deserts that reach temperatures up to 50°C (122°F), with some areas characterized by endless sand dunes. When project team members selected the location for a large new transportation project, little did they know that the site would be characterized by soft, nearly normally consolidated silt and clay extending below a thin sand crust. Searching for solutions, the design team elected to reinforce the subsurface with rammed aggregate pier ground improvement elements and wanted verification that the method would stand the test of prolonged static loads. Because the concrete pavements would serve to spread the load, a "zone load test" was performed, consisting of applying a uniform bearing pressure of 150 kPa (22 Psi) over a 7.5 m (25 ft) square concrete footing. Unlike individual pier load tests, the zone test allowed the project engineers the opportunity to confirm design parameter values under largeloading area conditions, a situation not often available to most designers. This paper presents the results of the zone load test, which may be interpreted to better understand design parameter values, and is of particular significance because it adds a valuable contribution to the relatively few numbers of "group load tests" available in the literature for ground improvement applications.
Citation
APA: (2024) Rammed Aggregate Pier Load Test Results
MLA: Rammed Aggregate Pier Load Test Results . Deep Foundations Institute, 2024.