RD Pile Wall – A Water Tight Retaining Wall Structure

- Organization:
- Deep Foundations Institute
- Pages:
- 10
- File Size:
- 948 KB
- Publication Date:
- Jan 1, 2017
Abstract
"Efficient use of land is constantly requiring more underground construction. Minimized execution time and disturbance to surroundings and nearby structures are essential benefits for all construction techniques. To meet the demands of a modern construction project, suppliers have to be able to provide high-quality and tailor-made products just on time. RD pile wall is a retaining wall based on drilled steel pipe piles which are connected to each other with special interlocking profiles. RD pile wall is a solution which enables penetration of overburden soil, dense fill layers including stones and boulders, and embedding into the bedrock in one single operation. Several test installations and laboratory tests have been made to develop the system and to test and improve the water tightness of the wall. Beside these tests, RD pile wall has also proven its reliability in almost 70 projects. Largest project so far has been Pasila Tripla project in Helsinki, Finland. A permanent retaining wall with surface area of 18,000 m2 (193,750 ft2), excavation depth of 21 m (68 ft) and over 17 m (56 ft) of water pressure was made with 711 mm (28”) and 406.4 mm (16”) pile sizes. Piles were delivered to site in one piece with lengths up to 33.5 m (110 ft).INTRODUCTIONExcavations in cramped city centers and in between of existing buildings and other structures are facing more and more challenges. Installation of sheet pile walls is often problematic or even impossible due to obstacles in ground from old structures and due to demand to extend the excavations to even deeper and harder soil layers. Also installations of secant pile walls are facing difficulties due to cramped construction sites and constantly tightening execution times.On the other hand, an efficient and reliable piling technique suitable for the demanding soil conditions described above, percussion drilling, has been developed since the 1960’s, and especially from the mid- 1990’s, when the concentric drilling method with the ring bit and pilot was introduced. A new retaining wall application, the RD pile wall, was developed by combining that drilling method with the widely used retaining wall solution based on steel pipe piles and welded interlocks (a pipe pile wall normally installed with vibratory or impact hammers).PRINCIPLE AND MAIN BENEFITS OF THE METHODRD pile walls can be used in all soil conditions. Most beneficial the system is in extremely demanding soil conditions where the installation of traditional retaining walls is challenging or even impossible. The RD pile wall is a combination of drilled steel pipe piles and interlocking sections as shown in Fig. 1.Individual RD piles are connected to each other with interlocks welded to the piles on the automated welding line at the workshop. The matching dimensions of the drilling system and interlocking sections allow the installation of RD piles through stones and boulders and even into the bedrock, if necessary, in a single operation. Installation is done by a down-the-hole (DTH) hammer using the centric drilling system and oversized ring bits or a drilling system consisting of a pilot bit and reamer wings shown in Fig. 2."
Citation
APA:
(2017) RD Pile Wall – A Water Tight Retaining Wall StructureMLA: RD Pile Wall – A Water Tight Retaining Wall Structure. Deep Foundations Institute, 2017.