Recent Progress In Thermal Diffusivity Measurement Of Molten Oxides By The Laser Flash Method

- Organization:
- The Minerals, Metals and Materials Society
- Pages:
- 10
- File Size:
- 385 KB
- Publication Date:
- Jan 1, 2003
Abstract
Precise thermal properties of molten materials are essentially required for analyzing the metal production process. These properties are also important as a clue to consider the dynamic structure of liquid materials. However, it is difficult to obtain the precise thermal diffusivity values of molten oxides at high temperature because of the experimental uncertainties arising from the bubble formation or the severe separation of radiative and conductive heat components. Recently a novel laser flash method has also developed for measuring thernnal diffusivity of molten oxides at high temperature. In this new technique, the sample is melted in a metal crucible and heated to the desired temperature. A single laser pulse is flashed on the bottom of the metal crucible and the infrared ray irradiated from the same bottom surface is measured for obtaining the temperature decay, from which the thennal diffusivity of the liquid sample can be estimated. The usefulness and validity of this new laser flash technique have been confirmed by obtaining the thermal diffusivity values of silicate melts in the wide temperature range between 773 and 1673 K.
Citation
APA: