[This paper describes preliminary tests at the Bureau's Experimental Mine to determine, under conditions that may prevail ira bituminous coal-mine heading, how small a quantity of fire damp may bring coal-dust into suspension and ignite to it. The results show that the explosion of as little as 150 cubic feet of an explosive mixture of gas and air containing 9 per cent natural gas may start a disastrous explosion Of coal-dust. This is a very small volume, of gas, to cause such a result. Let us suppose that this amount of exclusive mixture, was at the face of an entry which was 10 feet wide and the face was overcut to a depth of 6 foot and an upper layer of coal 2 1/2 feet thick had been removed, the recess so made would save a volume of 150 cubic feet. Furthermore, only 13 cubic feet of pure methane is needed in this volume to produce this 9 per cent explosive mixture.]