RI 5189 Galvanic Corrosion Properties Of Titanium In Organic Acids ? Summary

- Organization:
- The National Institute for Occupational Safety and Health (NIOSH)
- Pages:
- 21
- File Size:
- 2696 KB
- Publication Date:
- Jan 1, 1956
Abstract
The galvanic corrosion properties of titanium in contact with commercially pure aluminum, copper, or type 302 stainless steel in some of the common organic acids were investigated. Acids used in these experiments were 10 percent formic, acetic, lactic, citric; 1 percent oxalic and tartaric; and 9 percent oxalic. Electrode-potential measurements and several types of galvanic couple experiments were carried out. Solutions were aerated by three methods: Flow of air, flow of helium, and natural aeration. Work was done at 35° C. with couples consisting of equal areas of the 2 metals. Titanium was resistant to corrosion in most of the organic acids studied, whether alone or in contact with a dissimilar metal. However, titanium coupled with aluminum did corrode in 1- and 9-percent oxalic acid solutions. Contact with titanium usually caused aluminum to corrode by galvanic action. Copper was subject to galvanic attack in 10-percent acetic acid with a flow of air. Contact with aluminum to some solutions in which titanium is ordinarily inert and noble with respect to aluminum caused titanium to corrode
Citation
APA: