Abstract
This Bureau of Mines report describes how the reinforcement mechanisms of untensioned, full-column resin bolts were determined during one underground study. Both axial and transverse shear loadings were identified for two instrumented resin bolts that replaced standard resin bolts in an opera-ting room-and-pillar mining section. The strain responses of resin bolt steel cores to local axial and transverse shear loadings are described. This information was obtained from laboratory testing of resin bolts installations; it was also used to analyze the data from the underground test.
Citation
APA: