RI 8776 Evaluation of Radium and Toxic Element Leaching Characteristics of Florida Phosphogypsum Stockpiles

- Organization:
- The National Institute for Occupational Safety and Health (NIOSH)
- Pages:
- 23
- File Size:
- 9261 KB
- Publication Date:
- Jan 1, 1983
Abstract
The Bureau of Mines conducted studies to determine if phosphogypsum, a waste material from the processing of phosphate rock, contains hazardous toxic materials as defined by the Environmental Protection Agency (EPA) and whether leaching of these toxic materials and radium may occur. Samples of the phosphogypsum stockpiled material were evaluated using the EPA extraction procedure, atomic absorption, neutron activation, x-ray diffraction, and chemical and physical means. Radiological tests performed used both the germanium-lithium and emanation methods. The data show that the phosphogypsum stockpiles are not hazardous toxic waste as defined by EPA criteria. Trace elements and radium are not leached from the phosphogypsum stockpiles. Absorption of trace elements and radium by phosphogypsum is the major reason for their not being leached. The standard error of measurement of radium concentrations was 4.7 pCi/g.
Citation
APA:
(1983) RI 8776 Evaluation of Radium and Toxic Element Leaching Characteristics of Florida Phosphogypsum StockpilesMLA: RI 8776 Evaluation of Radium and Toxic Element Leaching Characteristics of Florida Phosphogypsum Stockpiles. The National Institute for Occupational Safety and Health (NIOSH), 1983.