Abstract

A joint effort by the U.S. Bureau of Mines (USBM) and the U.S. Mine Safety and Health Administration (MSHA) was undertaken to determine how well self-contained self-rescuers (SCSR's), deployed in accordance with Federal regulations (30 CPR 75.1714), held up in the underground environment with regard to both physical damage and aging. This report presents findings regarding laboratory-tested SCSR's in the fourth phase of testing from 1989 to 1993. The SCSR's were tested on human subjects and on a breathing and metabolic simulator (BMS). These results indicate that most of the apparatus, if they pass their inspection criteria, perform as expected except units with manufacturing defects. However, when the apparatus are carried in and out of the mine daily and stored at the working section, they may suffer abuse. Physical signs of abuse, unless extremely obvious, are frequently not detected by the miners or mine operators. In addition, some apparatus collected for this study had not been returned to the manufacturer in a recall effort for correction of a manufacturing defect. In both cases, the apparatus would have presented problems in emergency use. Recommendations include improved training in inspection procedures and better enforcement of recall notices.
Citation

APA: Nicholas Kyriazi  (2010)  RI 9499 - Self-Contained Self-Rescuer Field Evaluation: Fourth-Phase Results

MLA: Nicholas Kyriazi RI 9499 - Self-Contained Self-Rescuer Field Evaluation: Fourth-Phase Results. The National Institute for Occupational Safety and Health (NIOSH), 2010.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account