RI 9643 - Full-Scale Testing Of The Float Dust Deposition Meter

The National Institute for Occupational Safety and Health (NIOSH)
Robert A. Cortese Henry E. Perlee
Organization:
The National Institute for Occupational Safety and Health (NIOSH)
Pages:
16
File Size:
211 KB
Publication Date:
Jan 5, 1998

Abstract

Coal dust and float coal dust, produced during normal mining operations, in underground coal mines, are carried from the point of origin downstream by the ventilating air, where it deposits on the surfaces of the mine entry. In an explosion, this dust is lifted from the surfaces by the aerodynamic disturbances and, if of sufficient quantity, can continue to propagate the explosion. To prevent the surface coal dust from contributing, it must be inerted, typically by spreading pulverized limestone, i.e., rock dust, over the coal dust surface. To facilitate the dusting operation, the National Institute for Occupational Safety and Health (NIOSH), Pittsburgh Research Laboratory(PRL), developed an automated system that continuously monitors the accumulation of coal dust. This system could activate a rock-dusting machine that disperses rock dust into the ventilation air when dangerous deposits accumulate and deactivate the machine when sufficient inert has been deposited on top of the coal dust. The system consists of a microprocessor-controlled optical float dust deposition meter. This device measures the light intensity reflected from a deposited layer of dust. A standard cap lamp is used as a fixed-position light source. From the reflected light signal, the microprocessor determines the hazard level of the deposited layer and performs the appropriate action. Full-scale studies conducted in the Experimental Mine at PRL's Lake Lynn Laboratory, using alternating thin layers of rock dust and coal dust, successfully demonstrated the operation of the device. Based on the statistical data from these studies, a mathematical model was developed to predict long-term error in total rock dust content using this inerting procedure. Downwind dust dispersion was also examined to provide optimum placement of the dust sensors and to determine the need for better rock dust dispersion techniques.
Citation

APA: Robert A. Cortese Henry E. Perlee  (1998)  RI 9643 - Full-Scale Testing Of The Float Dust Deposition Meter

MLA: Robert A. Cortese Henry E. Perlee RI 9643 - Full-Scale Testing Of The Float Dust Deposition Meter. The National Institute for Occupational Safety and Health (NIOSH), 1998.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account