Silently Controlling Cracking Technology

- Organization:
- International Society of Explosives Engineers
- Pages:
- 8
- File Size:
- 109 KB
- Publication Date:
- Jan 1, 2000
Abstract
Based on the analysis of factors affecting the cracking performance of Silently Cracking Agent (SCA), a new SCA structural model is built and a study on the swelling mechanism of SCA and a method to increase swelling thrust by adding the swelling agent are presented. The reason for blow-out and the theory for avoiding blow-out are put forward. The new model improves the SCA theory and provides new method for developing effective SCA. Based on experiments made in laboratory, two types of SCA are developed. A Temperature Control Meter (TCM) has been developed to solve the alltemperature- crack problem after studying the suitable temperature scope of SCA.
Citation
APA:
(2000) Silently Controlling Cracking TechnologyMLA: Silently Controlling Cracking Technology. International Society of Explosives Engineers, 2000.