Solvent Extraction of Antimony by LIX 1104-SM from Sulphuric Solutions

- Organization:
- The Minerals, Metals and Materials Society
- Pages:
- 11
- File Size:
- 237 KB
- Publication Date:
- Jan 1, 1999
Abstract
The behavior and operability of LIX 1104SM extraction was studied at laboratory scale on the Solvent Extraction at Sb3+, from high concentration sulfuric acid. In order to evaluate the reactant batch tests were made at laboratory scale as well for extraction as for re-extraction of Sb3+. Experiences achieved were: extraction kinetics, temperature effects, selectivity tests and re-extraction selectivity. A extraction kinetics was found, reaching equilibrium in 2 min, high selectivity of Sb3+ extraction in front of Cue , existing As5+ co-extraction and Fe3+ At the re-extraction stage, equilibrium was reached in 3 min, getting high Sb3+ re-extraction efficiency with HCl concentrations within 6 and 8 M. A high selectivity was achieved on Sb3+ re-extraction in front of As+5, existing Fe+5 re-extraction.
Citation
APA: