System for Protecting People from Methane Explosion in Coal Mines

- Organization:
- Canadian Institute of Mining, Metallurgy and Petroleum
- Pages:
- 9
- File Size:
- 289 KB
- Publication Date:
- Aug 1, 2013
Abstract
Statistics shows that the majority of accidents with fatal outcome are caused by methane and/or coal dust explosion. This leads to assume that contemporary counter-explosion systems of various designs cannot be considered effective. Considering the growing threat of methane explosion in the coming years along with the development of deeper levels, the improvement of a system for protecting people in underground opening appears urgent. This paper presents the results of the testing of the Automatic System from Methane Explosion in Coal Mines. The protective system consists of: i) a wireless device for the detection of explosions and activation of a protective system, and ii) an absorber with a pyrotechnic device ensuring the discharge of dispersed water. The protective system, at the command of the initiation signal, produces tailored dispersing water mist with droplet sizes in the range of 25?400 ?m along selected tunnel sections.
Citation
APA: