The Evolution Of Drill Bit And Chuck Isolators To Reduce Roof Bolting Machine Drilling Noise

Society for Mining, Metallurgy & Exploration
R. Michael
Organization:
Society for Mining, Metallurgy & Exploration
Pages:
7
File Size:
571 KB
Publication Date:
Jan 1, 2010

Abstract

Among underground coal miners, hearing loss remains one of the most common occupational illnesses. In response, the National Institute for Occupational Safety and Health (NIOSH) conducts research to reduce the noise emission of underground coal-mining equipment, an example of which is a roof bolting machine. Field studies show that, on average, drilling noise is the loudest noise that a roof bolting machine operator would be exposed to and it contributes significantly to the operators? noise exposure. NIOSH has determined that the drill steel and chuck radiate a significant amount of noise during drilling. NIOSH and the Corry Rubber Corporation have developed a bit isolator that breaks the steel-to-steel link between the drill bit and drill steel and a chuck isolator that breaks the mechanical connection between the drill steel and the chuck. This effectively reduces the noise radiated by the drill steel and chuck and reduces the noise exposure of the roof bolter operator. The paper documents the evolution of the bit isolator and chuck isolator. Laboratory testing confirms that production bit and chuck isolators reduce the A-weighted sound level generated during drilling by 3.7 to 6.6 dB
Citation

APA: R. Michael  (2010)  The Evolution Of Drill Bit And Chuck Isolators To Reduce Roof Bolting Machine Drilling Noise

MLA: R. Michael The Evolution Of Drill Bit And Chuck Isolators To Reduce Roof Bolting Machine Drilling Noise. Society for Mining, Metallurgy & Exploration, 2010.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account