Thermoelectric Pyrometry ? Discussion

- Organization:
- The American Institute of Mining, Metallurgical, and Petroleum Engineers
- Pages:
- 2
- File Size:
- 75 KB
- Publication Date:
- Jan 11, 1919
Abstract
C. H. WILSON,* New York, N. Y. (written discussion?).-On page 2680, under the heading Junction Box and Zone Box, the authors say, with reference to the zone-box principle of connections between primary couple, compensator couple, and copper leads, which method in its appli-cation to a single couple is shown in Fig. 34, that if this principle is adopted for a multiple installation, so as to save compensating leads; a selective switch may be (and the inference is that it must be) inserted between the zone box and the different couples, putting the switch at an inconvenient point, or putting up with some complicated interlacing of connections.. Wilson-Maeulen Co. has employed the zone-box method extensively for several years and in none of the many multiple installa-tions has either of those alternatives been resorted to. Instead there has been used a method of wiring with the switch at the indicator and involv-ing no more complications than the junction-box method shown III