Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Confined Space And Inner-City Projects – Future Challenge And Opportunity For Diaphragm Walling

    By Alexander Blatt, Franz-Werner Gerressen

    Diaphragm walls are known as underground structural elements commonly used as retention systems for excavation pits and shafts and permanent foundation walls or elements. One can anticipate that globa

    Nov 1, 2022

  • DFI
    Bi-directional Load Testing Using Donut Super Cells For Hangzhou West Railway Station

    By Antonio Marinucci, Robin Mao

    The new Hangzhou West Railway Station, which is currently in the early stages of construction, will be located in the city of Hangzhou, China. To accomplish the ambitious goals of the project, the con

  • DFI
    Construction Of Large Drilled Shafts The 2nd Annual Mike O?Neill Lecture

    By Dan Brown

    Improvements in construction equipment and techniques in recent years have made possible the use of drilled shaft foundations in diameters and lengths not previously considered practical or feasible.

    Jan 1, 2013

  • DFI
    Development of Fiber-Reinforced Soil Improvement Using CSM Method

    By Toshio Yonezawa, Helmut Florian, Herbert Kuh, Masamichi Aoki, Takao Koono, Franz-Werner Gerressen

    "To increase the bearing capacity of the ground, soil improvement technique is often adopted. One advantage of soil improvement techniques is the fact, that the impact to the environment is low, as th

    Jan 1, 2015

  • DFI
    Ultimate Soil Pressures For Pile Groups In Soft Clay Subjected To Lateral Soil Movements

    By L. F. Miao

    Studies were carried out to investigate the ultimate soil pressure acting on pile(s) undergoing lateral soil movement in soft clay. A special apparatus has been designed to apply a uniform rectangular

    Jan 1, 2008

  • DFI
    Innovative Design for Retaining Structures using Combined Products

    By Clifford Taylor, Alexander Zöhrer

    "The execution of deep basement excavations under narrow conditions is one of the most challenging tasks in geotechnics. The vicinity of neighbouring buildings, roads, and underground structures such

    Jan 1, 1900

  • DFI
    Design And Analysis Of Cooling Tower Pile Foundations

    By Michael W. Oakland

    This paper summarizes the analysis and design of a pile foundation system for two 400 ft. diameter, 500 ft. high cooling tower using a detailed finite element analysis package. The cooling towers are

    Jan 1, 2010

  • DFI
    Finned Piles Response Subjected To Lateral Loading In Clayey Soils

    By Viswanadham B. V. S., Babu K. V

    Wind energy is one of the most economical renewable energy sources. In order to support wind turbines onshore or offshore open-ended monopile foundations are widely used. Unlike conventional structure

    Sep 1, 2022

  • DFI
    Behavior of Instrumented Deep Anchored and Strutted Diaphragm Wall in Soft Rock

    By Amr Al Degwe, Walid Jaber

    "INTRODUCTIONNSCC International Ltd. carried out the enabling works and constructed the foundation system for the Emirates Pearl Tower and Bab El Qasr Hotel in Abu Dhabi. Emirates Pearl Tower is a joi

    Jan 1, 2017

  • DFI
    New Pile for Reduced Underwater Noise

    By Dardis J. T. II, P. G. Reinhall

    "Impact pile driving of steel piles in marine environments produces extremely high sound levels in the water. It has been shown that current pile driving noise attenuation techniques provide limited n

    Jan 1, 2017

  • DFI
    South 196th/200th Street Corridor And Bridge Crossing, Kent, Washington

    By James Su

    The Green River Valley in Kent, Washington, is a fast growing area containing retail facilities, warehouse factories and industrial businesses, including the Boeing Space Center. Traffic from Intersta

    Jan 1, 1998

  • DFI
    CPT - Guided Installation Of Pressure-Grouted Displacement Piles

    By Mark M. Petersen

    As part of the addition of eight new combined cycle generating units at the Florida Power & Light Sanford Plant, 2,129 piles were to be installed. The existing plant elements were supported on driven

    Jan 1, 2002

  • DFI
    The Micropile Network: Practice Precedes Theory

    By Gary M. Weinstein

    Micropiles have seen increasing use for foundation support and slope stabilization applications over the past half century. Most often designed and installed in groups of vertical or battered elements

    Jan 1, 2003

  • DFI
    Dynamic Load Testing Of Augered Cast-In-Place Piles (Rausche)

    By Frank Rausche

    The more widespread use of Augered Cast-in-Place (ACIP) Piles has generated increased demand for improved quality control measures. These deep foundation elements are often relatively long and slender

    Jan 1, 2001

  • DFI
    Full Scale Load Test Program Confirms the Design of a Rigid Inclusions Solution for the Support of an MSE Wall in Southern New Jersey

    By Susan Rafalko, Mike Walker, John Sankey, Sherif Aziz, Alex Potter-Weight, Mary Nodine, Frederic Masse

    "After several successful projects on the Garden State Parkway and New Jersey Turnpike for support of single-stage MSE (Mechanically Stabilized Earth) walls using rigid inclusions (Controlled Modulus

    Jan 1, 2015

  • DFI
    Integration Of Real Time Pile Design By Means Of Building Information Modeling

    By Prof. Dr. -Ing. habil. Sascha Henke, Johannes Beck

    The growth of Building Information Modeling (BIM) during recent years opens possibilities for integrating new digitally driven design approaches. While parametric design and algorithmic design slowly

    May 1, 2022

  • DFI
    Augered Pile World Record Depth within a Soil Mix Basement

    By Andres M. Baquerizo, Jeremiah J. Filjones, Nicholas Feldt

    The Estates at Acqualina located in Sunny Isles Beach, FL, is comprised of two, ocean-front, 50-story, luxury towers with podiums and villas. With city regulations now requesting that above-grade floo

    Jan 1, 2019

  • DFI
    Geotechnical Exploration Phase Drilled Shaft Load Testing

    By Walter E. Vanderpool

    Full scale load tests are frequently performed immediately prior to deep foundation construction to verify the design assumptions. Occasionally, load tests are performed during design development and

    Jan 1, 2011

  • DFI
    Applications of Known Concepts for Management of Construction Vibrations

    By Mark R. Svinkin

    "Construction equipment and operations usually produce soil and structural vibrations which may harmfully affect various structures and also the content of buildings and houses. The level of structura

    Jan 1, 2016

  • DFI
    Size And Loading Rate Effects Observed In Plate Load Tests On A Fill

    By Kazuyuki Matsuzawa

    A series of plate loading tests were carried out on a loam ground in order to investigate the influences of the plate size and the loading rate on the observed load-settlement relations. Two circular

    Jan 1, 2006