Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Bearing And Friction Design Capacity Software For Helical Anchors And Piles

    By Gary L. Seider

    Chance, a Division of Hubbell Power Systems, Inc., in conjunction with Sailors Engineering, Inc. has updated its Helical Design Capacity Software. This latest version, ?HeliCAP® v2.0?, is a state-of-

    Jan 1, 2007

  • DFI
    Recovery Efforts At The World Trade Center "Bathtub"

    By George J. Tamaro

    In 1967 the Port Authority of New York and New Jersey undertook the construction of the World Trade Center (WTC) diaphragm walls, installation of the lateral support system and the excavation of the s

    Jan 1, 2002

  • DFI
    Holistic Thermal Assessment And Control Of Ground Freezing For A New Underground Station

    By Christian Leble, Dr. -Ing. Jakob Vogelsang, Dr. -Ing. Oksana Solt, Dipl. -Ing. Joachim Meier, Dr. -Ing. Wolfgang Orth

    In the course of closing the gap between the Brandenburg Gate and Alexanderplatz, the Museum Island station was built by Implenia Construction GmbH. The tunneling for the platform hall took place on a

    May 1, 2022

  • DFI
    Innovative Cofferdams Used On The I-205 Columbia River Bridge

    By Robert Bittner

    The following is a report on the development of two unique and separate cofferdam systems used in the construction of the marine foundations for the I-205 Columbia River Bridge at Portland, Oregon for

    Jan 1, 2013

  • DFI
    Instrumented Driven Steel Tube Piles At Canary Wharf, London

    By A. R. Gaba

    Phase I of the Canary Wharf development in London's docklands involves the construction of six fifteen storey buildings located predominantly over water of the West India Docks. The buildings are

    Jan 1, 1989

  • DFI
    Experiences With Heavy Drop Hammer Testing Of Rock-Socketed Shafts

    By Frank Rausche

    Since the early 1980s, when the Road Construction Authority of Victoria authorized the dynamic proof testing of roughly 100 drilled shafts of 1.5 m diameter and typically 60 m length in Melbourne Aust

    Jan 1, 2006

  • DFI
    Using Dynamic Pile Testing To Overcome Surprising Soil Variations

    By H. (Sam) Salem

    A site investigation for a wide and tall hotel building, in the San Juan Bay area, Puerto Rico, indicated a soil profile of silty clay on sand, soft and loose enough to require piled foundations. The

    Jan 1, 2008

  • DFI
    Suwanee American Cement Plant, Branford, Florida: A Case Study Of Large Diameter Continuous Flight Auger Design Build Foundations

    By Gordon King

    This paper presents a case study of large diameter continuous flight auger (CFA) piles and drilled shafts utilized for foundation support of a series of heavily loaded cement plant structures at the S

    Jan 1, 2003

  • DFI
    Deep Foundation Underpinning Support For Fort Monroe, Virginia YMCA Historic Building Renovation

    By David C. Kraft

    Atlas Systems, Inc. (ASI) resistance type piers were used to underpin a 100 year old historic structure at Fort Monroe, Virginia. This 3-story structure with basement was underpinned with 155 steel tu

    Jan 1, 2002

  • DFI
    OPA Contender Features Innovative ACIP Pile Test

    By Andres M. Baquerizo, Matthew E. Meyer, Carlos Ortiz

    "The Metropolitan Miami development, a downtown mixed-use complex developed by Miami-based MDM Development Group, has weathered the economic downturn by adapting to the needs and pressures of the loca

    Jan 1, 2012

  • DFI
    Hybrid Shoring System for a Deep Temporary Excavation

    By Nadir Ansari, Brian W. Wilson, Marina S. W. Li

    "A hybrid Deep Mixing (DM) shoring system was recently constructed for a high-rise development in downtown Vancouver, British Columbia, Canada for the temporary support of a five-level basement excava

    Jan 1, 2017

  • DFI
    Ground Freezing: The Use of Liquid Nitrogen Systems Converted To Brine

    By Joseph A. Sopko

    There has been a trend in recent years in performing the initial formation freezing using liquid nitrogen (LIN) and then converting the system to circulating refrigerated brine. While proponents of th

    Jan 1, 2019

  • DFI
    Stemmers Run Steel Sheet Pile Cofferdam And Trestle

    By Jennifer Peirce Brandt

    Project documents and the United States Army Corps of Engineers? permit for construction of the Stemmers Run Relief Wastewater Force Main across the Back River in Baltimore County, Maryland specified

    Jan 1, 2008

  • DFI
    A Sound Concept that Deserves to Be Expanded

    By Deep Foundation

    Whenever an organization launches an initiative, the question arises whether that initiative has staying power. Or is the initiative, as is quite often the case, merely a fad; that is, just an activit

    May 1, 2023

  • DFI
    Use of a Reinforced Jet Grout Excavation Support System for a Major Sewer Line Repair

    By Richard Brink, Eric M. Klein, Kenneth B. Andromalos

    "A portion of the roof for a 129 x 144-inch, nearly 100-year-old sewer outfall in the City of Baltimore had deteriorated to the point that it resulted in the development of a large sinkhole in a resid

    Jan 1, 2005

  • DFI
    Effective Sampling, Testing and Specification Approaches for Deep Mixing at Kitimat LNG, BC

    By Randy R. Williams, Brian W. Wilson, George M. Filz, Marina S. W. Li, Donald A. Bruce

    "In-situ wet grab sampling and post-installation coring of soil-cement structures are typically carried out for Quality Control (QC) and Quality Assurance (QA) of deep mixing (DM) schemes. Wet grab sa

    Jan 1, 2015

  • DFI
    Session 31 "Grout Mixtures and Materials 2"

    By Lois G. Schwarz

    I did not make studies about this parameter but I can say that some researchers recommend using low C3A cements to repair masonry mortar in order to reduce a possible combination with sulphate that ca

    Feb 10, 2003

  • DFI
    Non-Destructive Testing Methods for Drilled Shaft and ACIP Piles (34748882-cb96-4081-9967-58c48901bc15)

    By George Piscsalko

    "Quality control of drilled shafts and ACIP piles is greatly dependent upon the practices of the site personnel. In many applications it is difficult to properly inspect the shaft prior to concreting,

    Jan 1, 2017

  • DFI
    Seven Mile Dam Retrofit - A Global Challenge

    By Arvindh Gupta

    BC Hydro proposed to improve the stability of the existing Seven Mile Dam with 54 corrosion protected, re-stressable anchors comprising 92/0.6? strands each, in phase 2 of the program. Being globally

    Jan 1, 2004

  • DFI
    Structure Support on Laterally Swept Piles

    By Morgan L. Race, Matthew R. Glisson

    "Most driven pile projects have plumbness limits from 0.25 in/ft (21 mm/m) to 0.5 in/ft (42 mm/m) to control bending stresses. For two projects, the project teams performed static load testing to eval

    Jan 1, 2017