Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • SME-ICGCM
    Stability Mapping System

    By Quanxi Wang

    This paper presents a new stability mapping system which tightly integrates structural and geologic mapping with geo- mechanical stress analysis for use in support design and mine plan- ning. The stru

    Jan 1, 2005

  • SME-ICGCM
    Investigation of Electromagnetic Emissions in a Deep Underground Mine (0366ea57-3ba7-4a00-bec7-825a048e7e26)

    By Douglas Scott

    Highly stressed rock in stopes continues to be a primary safety risk for miners in underground mines because it can result in failures of ground that lead to both injuries and death. Spokane Research

    Jan 1, 2004

  • SME-ICGCM
    A Simple Finite Element Model For Predicting The Behaviour Of Hydraulically Powered Coalmine Supports

    By Brian G. D. Smart

    A scheme is presented whereby the complexities of design and operation of a hydraulically powered coalmine support are modelled using the finite element method. This enables predictions to be made of

    Jan 1, 1992

  • SME-ICGCM
    Evaluation Of The Strength Behaviour Of Monolithic Packs (af92f0dd-9b80-4922-891e-7d098de9b5e7)

    By S. I. Al-Ameen

    Monolithic packing systems have gained in popularity as a gate side packing method, However, there has been no detailed investigation to assess their underground strength behaviour. This work includes

    Jan 1, 1992

  • SME-ICGCM
    Behavioral Aspects of Roof/Rib Injuries--Implications for Training Utilizing Stereoscopic Photography

    By Edward A. Barrett

    A significant number of injuries resulting from fa118 of roof and rib may be avoided by modifying the reactive behavior of miners as they encounter potentially hazardous ground conditions. In 1984-85,

    Jan 1, 1986

  • SME-ICGCM
    Analysis of Roof Falls at and Recommendation of Roof Control Plansfor Rofomex Posphate Mine

    By Jinsheng Chen

    For underground openings, many factors can cause roof failure and thus roof falls. The most common factors related to Mother Nature are weak roof lithology, geological structures, and an abnormal in-s

    Jan 1, 2011

  • SME-ICGCM
    Tekflex As A Sprayon Screen Replacement In An Underground Hard Rock Mine

    By Chris Pritchard

    Falconbridge Ltd., a major base metal producer in the Sudbury Basin of Ontario, Canada, identified a need to find a safe and cost effective replacement for welded-wire mesh used to support loose groun

    Jan 1, 1999

  • SME-ICGCM
    Renewed Interest In Prop Supports As A Replacement For Wood Cribs

    By Thomas M. Barczak

    Wood cribs have been the dominant form of supplemental support in coal mining for many years. Recently, there has been a renewed interest in prop supports as a replacement for wood cribbing due to the

    Jan 1, 1995

  • SME-ICGCM
    3D FEM Simulation For Fully Grouted Bolts

    By Khaled Morsy

    Most of the available numerical codes simulating the reinforcing effect of fully grouted bolt are accomplished by a series of bar elements which are connected along their length to the host rock by sh

    Jan 1, 2004

  • SME-ICGCM
    The Impact Of Variability In Coal Strength On Mine Planning And Design - A Case History

    By David A. Newman

    Strength and physical property testing of coal is conducted regularly by the Arch Mineral Corporation as part of reserve exploration. Pillar design and mine layout are the primary applications for the

    Jan 1, 1993

  • SME-ICGCM
    Microseismic Monitoring of Mountain Bumps and Bounces: A Case Study

    By J. L. Condon

    The Bureau of Mines, through in-house and contract research, monitored mountain bump-prone areas of the Olga #2 Mine, near Welch, WV, using microseismic techniques for 15 months during 1985 and 1986.

    Jan 1, 1987

  • SME-ICGCM
    Preventing Falls Of Ground In Coal Mines With Exceptionally Low-Strength Roof: Two Case Studies

    By Christopher Mark

    Mines with exceptionally low-strength roof (UCS <3,500 psi and CMRR <40) are much more likely to struggle with roof falls than other mines. Weak-roof is a particular problem for many room and pillar m

    Jan 1, 2004

  • SME-ICGCM
    Continuing Development of Innovative Cable Support Systems

    By John G. Oldsen

    Passive cable bolting and active cable trusses have been used in roof support for more than two years Excellent roof control has been experienced by many coal operations. This paper covers the new

    Jan 1, 1997

  • SME-ICGCM
    Weatherability Test of Rocks for Underground Mines

    By Kot F. Unrug

    The shale response to moisture changes and the major finding of the appropriate research concerning this subject are briefly reported in this paper. Also described are mine ambient atmospheric condit

    Jan 1, 1997

  • SME-ICGCM
    Effect of the Approaching Longwall Faces on Barrier and Entry Stability

    By Klaus-Dieter Beck

    RAG American Coal Holding, Inc. affiliates operate two longwall mines in the Pittsburg seam in Pennsylvania, the Cumberland mine and the Emerald mine. A unique situation in longwall operation occurred

    Jan 1, 2004

  • SME-ICGCM
    The Autowarning Telltale: A New Safety Monitoring Device for Pillar Extraction Operations

    By David Bigby

    Room and pillar mining with full pillar extraction is one of the most hazardous systems of underground coal mining, a significant hazard being the potential for sudden goaf override. The Autowarning

    Jan 1, 2011

  • SME-ICGCM
    Longwall Production, Maintenance, And Roof Control System

    By W. Mark Hart

    The current Automatic Data Acquisition system developed by some support manufacturers make it possible to monitor and record changes in leg pressure, DA RAM stroke in every shield and shearer position

    Jan 1, 1994

  • SME-ICGCM
    Extended Cut Out Distances In Continuous Miner Sections In South African Collieries

    By Ismet Canbulat

    The cut out distance in the continuous miner sections in South African collieries is limited to 12 m. However, this distance can be extended to 24 m by the permission of the Department of Mineral and

    Jan 1, 2000

  • SME-ICGCM
    Method Of Selecting Suitable Types Of Powered Supports At Longwall Faces

    By S. M. Hsiung

    A model (support selection model) for the selection of suitable types of powered supports under various geological conditions is proposed. This model is developed by evaluating the support, performanc

    Jan 1, 1988

  • SME-ICGCM
    Determination Of Classification Parameters For Clay - Bearing And Stratified Rock Mass

    By Erdal Unal

    In underground mining today, safety and economical aspects demand a better understanding of the rock-mass conditions, particularly for design of underground mine openings excavated in weak and stratif

    Jan 1, 1990