Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
-
Installation And Design Guidelines For Cable Dowel Ground Support At ZC/NBHCBy Askew J. E
All facets of current practices of cable dowelling at The Zinc Corporation, Limited and New Broken Hill Consolidated Limited are re- viewed. This includes materials specific- ations, installation pra
Jan 1, 1977
-
Installation and Efficiency of Common Helical Pile CouplingsBy Jason Herron, Joseph Brown
The common couplings for joining sections of helical piles with an outside diameter of 6.625 inches and 8.625 inches are square on square, flange to flange, external pipe sleeve, internal pipe sleeve,
Jan 1, 2019
-
Installation And Operational Result Of Lindarctm Real Time Laser Off-gas Analysis System At Acciaierie Bertoli Safau - Abs (Italy) Electric Arc FurnaceBy Daniele Tolazzi
In today’s highly competitive market situation, it is of outmost importance for EAF steel makers to optimise their processes in order to reduce operating costs and to improve safety and reliability of
Aug 16, 2017
-
Installation and Preliminary Results of a Novel Fiber Optic Distributed Strain Monitoring System in an Active Underground Room and Pillar Metal MineBy Taghi Sherizadeh, Paul Brooks, Dogukan Guner, Samuel Nowak
Large excavations are well known to result in rock mass deformations which can present challenging situations for mine personnel. Most of the currently available ground movement monitoring devices fai
-
Installation Of 0.84 M (33 In) Cyclones On The Primary Grinding Circuit At Cyprus Sierrita CorporationBy L. N. Hill
The classifiers on the primary grinding circuit at Cyprus Sierrita have been upgraded from 0.66 m (26 in) diameter hydrocyclones to 0.84 m (33 in) diameter hydrocyclones. This has resulted in a 4.3 %
Jan 1, 1994
-
Installation of 10 Feet Diameter CIDHs in Soft Clay Using Rotator/Oscillator on TrestleBy Babak Mamaqani, Pirooz Barar
The Moanalua trestle spanned over Moanalua Stream, Honolulu, HI and was designed to accommodate construction of five 10 feet diameter cast in drilled hole (CIDH) piers as a part of Honolulu Authority
Jan 1, 2019
-
Installation Of A 350 T Bof Converter At Arcelormittal PolandBy Günther Staudinger
Danieli Linz Technology has been honored at 4.1.2013 with the first contract for the exchange of a 350 t BOF converter for ArcelorMittal Poland Dabrowa Gornicza on a turnkey basis. This paper describe
Jul 29, 2018
-
Installation Of A New 80 T Mrp-l Converter At Aperam TimoteoBy Günther Staudinge
Aperam is a global player in producing of stainless, electrical and special steel qualities. The steelmaking plant in Timoteo Brasil is equipped with one AODconverter for stainless steel and one MRPL-
Aug 17, 2017
-
Installation Of A New Surface Fan At The Homestake Gold Mine ? IntroductionBy Greg Struble
The Homestake Gold Mine is one of the deepest and most extensively developed hardrock mines in North America. The mine is divided into five divisions which produce a total of 1.7 million metric tons o
Jan 1, 1987
-
Installation Of A Supervisory Control System At A Gold Pressure Oxidation Plant (edba5c85-6442-4bfd-bdfb-2b55fb328e40)By M. Spangler
FirstMiss Gold installed a supervisory control system based on Pavilion Technology's Process Insights neural network software and Oil System's PI data historian. The primary goal of the syst
Jan 1, 1995
-
Installation of Flash Flotation Units at the Louvicourt ConcentratorBy Bernard Dallaire, Jean Cayouette, Sylvain Duchesne
"Louvicourt Mine's concentrator, located near Val d'Or, Quebec, treats an average of 4,300 tonnes of ore per day composed mainly of copper, zinc, gold and silver. An analysis of concentrator revenues
Jan 1, 2001
-
Installation of Paste Backfill Technologies in a High Rock Temperature and Hard Rock Mine, Toyoha, JapanBy Jiro Yamatomi, Susumu Takemura, Osam Sakai, Hiroshi Shimotori, Yoshio Otsuka
The Toyoha Mine is operated under extremely high rock temperature. The geothermal heat is 10 to 20 times more active than the average of the Japanese Islands. The highest temperature ever observed in
Jan 1, 2001
-
Installation of Secant Pile Wall in Rock Adjacent to Fragile BuildingBy Chu E. Ho, Alfredas Daugiala, Nicola Ebanks
"The construction of an ancillary structure for the new Second Avenue Subway Line in Manhattan, New York City involved a deep excavation in highly variable rock conditions adjacent to a fragile masonr
Jan 1, 2016
-
Installation of Shaft Bottom Steel Prior to Shaft SinkingBy D. M. Ziebarth
"Normal sequence of operations to develop a new underground mine is: construct and outfit headframe for shaft sinking, sink shaft, construct and outfit shaft sump, develop shaft station and shaft bott
Jan 1, 2019
-
Installation Of Three Up To 120M Deep Diaphragm Wall Shafts, With Diameters Between 8M And 35M At Woodsmith Mine In North Yorkshire (England)By Gustav Jahner, Michael Baltrusch, Norbert Hoffmann
Near the port city of Whitby in the north-east of England, Anglo American (AA) is setting up the deepest mine in the UK, which will have a depth of 1,500m. The purpose of the project is to extract and
Sep 1, 2022
-
Installation Parameters, Pile Performance and Importance of TestingBy Maurice Bottiau
"Abstract When addressing the performance of deep foundations, many parameters play a role, from adequate soil investigation to performance monitoring and testing. The correct understanding of pile co
Jan 1, 2014
-
Installation Techniques - 6.1 The Basic PhilosophyThe investment involved in any communication system represents a considerable sum. Even though it is desirable that the system work properly each and every time it is called into use, some failures ar
Jan 1, 1984
-
Installation, Operation And Maintenance Problems With Large Vibrating Screens In Mineral Processing ApplicationsBy J. W. Scott
The problems involved in installing, maintaining, and operating large vibrating screens have been summarized and discussed, based on a survey of current use of such screens in selected North American
Jan 1, 1983
-
Installing And Testing Multi-bar High Capacity Rock TiedownsBy Andrew Pontecorvo, Steven Lowe, David Sposito
Buildings with large height-to-width ratios require foundations with significant uplift resistance. This paper presents a case study of the permanent rock tiedowns installed for One Manhattan West, a
-
Instantaneous Access To Maintenance DataBy R. Gilges
The implementation of effective techniques for meeting the maintenance requirements of the new Utah Copper Division smelter, one of the largest in the Western Hemisphere, is a goal of the smelter mana
Jan 1, 1977