Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Design Of An Unbraced Elliptical Slurry Wall Cofferdam For Deep Pump Station Construction

    By Gordon Chen

    As part of a value engineering envisioned by East Coast Slurry, Weidlinger Associates, Inc. designed a unique elliptical slurry wall cofferdam for construction of the 65 ft. deep MWRA North Dorchester

    Jan 1, 2010

  • DFI
    Design Method For Bridge Abutment Foundation Piles Subjected To Lateral Earth Pressure ? Synopsis

    By T. Matsui

    Many existing bridge abutments on the soft ground laterally move and their many damage examples have been reported. An essential cause for the troubles of the lateral movements may be the lack of exam

    Jan 1, 2010

  • DFI
    Permanent Earth Retention for Deep Excavation Installed Within Minimal Right of Way Limits

    By Thomas D. Humbert, Christopher J. Ramsey

    Construction of a new underground parking structure in State College, Pennsylvania, is situated on a site constrained by limited ROW and required excavations ranging in depth from 25 ft to 40 ft. Addi

    Jan 1, 2019

  • DFI
    Statnamic Load Testing Of Strain Instrumented Large Diameter Bored Shafts - Synopsis

    By Matthew Janes

    Statnamic load testing is becoming widely accepted as a method to quickly and economically determine the load-deflection behaviour and ultimate static resistance of high capacity deep foundations. Str

    Jan 1, 1996

  • DFI
    Theoretical Simulation Approach For Load Settlement Characteristics Of Piles In Shale Deposits. - Synopsis :-

    By Subrata Ray

    A large no of power stations are being set up in Chandrapur area having coal deposits. Several industries are also coning up in this area. The subsurface is geologically formed under Gondwana system a

    Jan 1, 1996

  • DFI
    Investigation Of Recycled Plastic Piles For Support Of Structures In Expansive Shale Environments

    By Eric Brandner

    Expansive soil formations can be found throughout the United States. When subjected to wetting, many of these formations have the potential to swell and exert large uplift forces which can significan

    Jan 1, 2009

  • DFI
    Ground Improvement Design and Construction for Seattle’s Elliott Bay Seawall Replacement and Retrofit

    By Andrew Malinak, William Perkins

    Seattle’s Elliott Bay Seawall protects the 1½ miles of downtown waterfront between South Washington and Broad streets. The seawall supports the urban waterfront and infrastructure, including the Alask

    Jan 1, 2018

  • DFI
    2D and 3D Finite Element Analysis for Cantilever Slurry Walls in Cohesionless Soil

    By Mostafa Mossaad, Ali Helwa, Manal Salem

    Support of excavation (SOE) design practice tends to model SOE elements using two-dimensional (2D) analyses to avoid the complexity associated with three-dimensional (3D) analyses. Such practice overl

    Jan 1, 2018

  • DFI
    Session 8 " Jet Grouting and Deep Mixing"

    By Masaki Kitazume

    Five papers were presented orally to the topics of Jet Grouting and Deep Mixing. The session was started with a brief introduction by the moderators. Following the oral presentation, floor discussions

    Feb 10, 2003

  • DFI
    Composite Foundations For Uplift And Compression In Soft Soils And Swampy Terrain ? Synopsis

    By H. S. Radhakrishna

    Foundations supporting power transmission and communications towers are subjected to both compression and uplift loads, often of a cyclic nature. Some novel foundations, combining the beneficial featu

    Jan 1, 2010

  • DFI
    Practical Soil Nail Wall Design And Constructability Issues

    By Walter G. Kutschke

    Four significant soil nail wall projects in the eastern United States were recently completed with a combined area of 175,000 square feet of finished shotcrete surface. These projects required the us

    Jan 1, 2007

  • DFI
    Deterministic Analysis for Liquefaction and its Mitigation by Suitable Foundation Type in Bangladesh

    By Arpit Parikh

    "Ground Water or Pore water pressure development in Sandy Soil formation is Critical situation in foundation analysis and design.Moreover it become severe while associated with higher liquefaction pro

    Jan 1, 2017

  • DFI
    Foundation Retrofitting Using Micropiles - A Case History

    By Mohammad Nasim

    Vertical expansion of existing structures frequently requires foundation retrofitting to enhance the capacity of existing foundations for supporting additional loads. Owing to their small diameter, a

    Jan 1, 2008

  • DFI
    Recent Advances In Quiet & Vibration-Less Steel Pile Installation & Extraction

    By Ray. K. Filip

    The concept of installing a steel sheet pile retaining wall into the ground by "pressing" has resulted in the development of various equipment solutions over the last thirty years e.g. Taylor Woodrow

    Jan 1, 2006

  • DFI
    Use Of Auger Pressure Grouted (APG) Piles Inside An Existing Operational Structure

    By Lawrence P. Goldfarb

    The City of Alexandria, Virginia, Public Safety Center (PSC) is a 64,000 square foot facility that houses the Police Department, Office of Sheriff and the Office of Magistrate. In addition, the center

    Jan 1, 2009

  • DFI
    Self Drilling Soil Nail Systems To Retain Caving Soils

    By Ali Porbaha

    The use of soil nailing technology as a cost effective alternative for excavation support and slope stabilization has substantially increased in the United States during the last decade. For example,

    Jan 1, 2006

  • DFI
    Use Of Cone Penetration Test (CPT) Results For Accurate Assessments Of Pile Capacities

    By Anand J. Puppala

    This paper provides information on various evaluation studies conducted to assess the CPT based interpretation methods. Salient findings from these evaluations are summarized. Additionally, a comprehe

    Jan 1, 2002

  • DFI
    Test Pile Program Carrier Pier And South Wharf Naval Station Puget Sound Everett, Washington

    By David G. Winter

    The first test pile for the carrier pier and south wharf at NAVSTA Puget Sound was driven on December 27, 1989, and the final pile was tested on February 26, 1990. Implementation and modification of t

    Jan 1, 1990

  • DFI
    Building Above And Excavating Below An Iconic Building In Manhattan

    By John S. Civetta, Seth Martin, Marc J. Gallagher, Arthur J. Alzamora, Ronald Peralta

    The Crown Building, built circa 1921, is a 26-story iconic building located at West 57th Street and Fifth Avenue in the heart of Manhattan. The paper highlights collaboration between the geotechnical

  • DFI
    Pile Foundation Response to Ground Vibration from Rock Blasting

    By Anthony T. C. Goh, Zhiye Zhao, Laddu B. Jayasinghe, Hongyuan Zhou, Yilin Gui

    "Ground vibrations from blasting are undesirable and they are very short in duration with high principal frequencies and high amplitude. Structural response to that kind of excitations may differ sign

    Jan 1, 1900