Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
-
RI 9412 - Response of Underground Fire Sensors: An EvaluationBy Ronald S. Conti
This U.S. Bureau of Mines report discusses the results of research conducted in the Bureau's experimental mine at Lake Lynn Laboratory on the response of fire sensors to simulated mine fires, whi
Jan 1, 2010
-
RI 9413 - Effects Of Horizontal Stress Related To Stream Valleys On The Stability Of Coal Mine OpeningsBy G. M. Molinda
The U.S. Bureau of Mines conducted an investigation to determine the nature and frequency of coal mine roof failure beneath valleys. A mechanism for this failure and suggestions for controlling this p
Jan 1, 2010
-
RI 9414 - Evaluation of Structures for Roof-Fall AreasBy Richard A. Allwes
This U.S. Bureau of Mines report presents the results of structural analyses and full-scale physical tests conducted on a steel-set arch and tri-set. The purpose of the analyses and tests was to evalu
Jan 1, 2010
-
RI 9415 - Cause of Floor Self-Heatings in an Underground Coal MineBy C. P. Lazzara, Y. Miron, A. C. Smith
This report presents a U.S. Bureau of Mines study to identify the causes of self-heating events beneath the floor of a deep underground coal mine. Mine samples from both heated and unheated areas w
Jan 1, 1992
-
RI 9415 - Cause of Floor Self-Heatings in an Underground Coal Mine (f50c25d5-acc4-494c-901f-26455f6e764b)By Y. Miron
'This report presents a U.S. Bureau of Mines study to identify the causes of self-heating events beneath the floor of a deep underground coal mine. Mine samples from both heated and unheated are
Jan 1, 2010
-
RI 9416 - Cause of Floor Self-Heatings in an Underground Coal MineBy Jeffrey Shawn Peterson
The testing procedures of the U.S. Mine Safety and Health Administration specify that intrinsic safety acceptance tests be conducted using a standard tungsten-cadmium electrode configuration in the br
Jan 1, 1992
-
RI 9416 - Influence of Electrode Material on Spark Ignition ProbabilityBy Jeffrey Shawn Peterson
The testing procedures of the U.S. Mine Safety and Health Administration specify that intrinsic safety acceptance tests be conducted using a standard tungsten-cadmium electrode configuration in the br
Jan 1, 2002
-
RI 9416 - Influence Of Electrode Material On Spark Ignition Probability (450608c8-d644-422e-9fbc-5a903cc93f17)By Jeffrey Shawn Peterson
The testing procedures of the u.s. Mine Safety and Health Administration specify that intrinsic safety acceptance tests be conducted using a standard tungsten-cadmium electrode configuration in the br
Jan 1, 2010
-
RI 9417 - Frictional Ignition of Natural Gas-Air Mixtures by Alternative Coal-Cutter Bit Shank MaterialsBy L. Garner McDonald
The U.S. Bureau of Mines tangentially impacted potential coal-cutter bit shank materials against sandstone to investigate the potential of the materials to ignite natural gas by a friction-generated h
Jan 1, 1992
-
RI 9417 - Frictional Ignition Of Natural Gas-Air Mixtures By Alternative Coal-Cutter Bit Shank Materials (78438c08-0460-4e7b-987b-fc86d7400932)By L. Garner McDonald
The U.S. Bureau of Mines tangentially impacted potential coal-cutter bit shank materials against sandstone to investigate the potential of the materials to ignite natural gas by a friction-generated h
Jan 1, 2010
-
RI 9418 - Canopy and Base Load Distribution on a Longwall ShieldBy David F. Gearhart, Thomas M. Barczak
This U.S. Bureau of Mines report examines the roof and floor contact pressure provided by the interaction of a shield with the surrounding strata. Controlled forces were applied to an 800-ton two-leg
Jan 1, 1992
-
RI 9418 - Canopy and Base Load Distribution on a Longwall Shield (14a010d7-73b6-499e-aefd-dc1cae4d5747)By Thomas M. Barczak
This US. Bureau of Mines report examines the roof and floor contact pressure provided by the interaction of a shield with the surrounding strata. Controlled forces were applied to an 800-ton two-leg s
Jan 1, 2010
-
RI 9419 - Gallium and Germanium Recovery From Domestic SourcesBy D. D. Harbuck
To decrease reliance on foreign sources for the strategic and critical metals gallium and germanium, the U.S. Bureau of Mines identified and developed processing technology for two domestic sources of
Jan 1, 2010
-
RI 9420 - Teleoperation of a Highwall Mining SystemBy Albert L. Brautigam, Michael C. Leigh, August J. Kwitowski
The U.S. Bureau of Mines developed and tested a teleoperating system to control a new highwall mining system. A remote operator was provided out-of-sight sensory information and control of coal extrac
Jan 1, 1992
-
RI 9420 - Teleoperation of a Highwall Mining System (606217b0-2b55-4b41-acf7-114b1f0ce11d)By August J. Kwitowski
The U.S. Bureau of Mines developed and tested a teleoperating system to control a new highwall mining system. A remote operator was provided out-of-sight sensory information and control of coal extrac
Jan 1, 2010
-
RI 9421 - Mine Fire Diagnostic Applied to the Carbondale, PA Mine Fire SiteBy Ann G. Kim, Thomas R. Justin, John F. Miller
The U.S. Bureau of Mines applied its mine fire diagnostic method to an abandoned anthracite mine fire site in Carbondale, Lackawanna County, PA. The technique to locate fires in abandoned coal mines a
Jan 1, 1992
-
RI 9421 - Mine Fire Diagnostics Applied to the Carbondale, PA, Mine Fire SiteBy Ann G. Kim
The U.S. Bureau of Mines applied its mine fire diagnostic method to an abandoned anthracite mine fire site in Carbondale, Lackawanna County, P A. The technique to locate fires in abandoned coal mines
Jan 1, 2010
-
RI 9422 - Apparatus for Measuring Diesel Tailpipe Emissions in Underground MinesBy T. R. Taubert, D. H. Carlson, J. H. Johnson
The U.S. Bureau of Mines and Michigan Technological University (MTU) are collaborating to develop an apparatus for measuring diesel tailpipe emissions in underground mines. A tailpipe emissions measur
Jan 1, 1992
-
RI 9422 - Apparatus for Measuring Diesel Tailpipe Emissions in Underground Mines (208f1c0e-46a9-49e2-aa32-924d3148492b)By D. H. Carlson
The U.S. Bureau of Mines and Michigan Technological University (MTU) are collaborating to develop an apparatus for measuring diesel tailpipe emissions in underground mines. A tailpipe emissions measur
Jan 1, 2010
-
RI 9423 - Hybrid Fiber-Optic Electrochemical Carbon Monoxide MonitorBy J. E. Chilton, C. R. Carpenter
The U.S. Bureau of Mines has developed an intrinsically safe carbon monoxide (CO) monitoring system for mines by coupling a fiber-optic data telemetry (FODT) system with a prototype electro- chemical
Jan 1, 1992